Measurement Range: Wet 0.01-2000μm   Dry 0.1-2000μm

It is widely applicable to high-end application scenarios such as research institutes, university laboratories, and enterprise R&D centers and quality testing institutions.

Products Description

Winner2309C Large-range Modular Wet and Dry Laser Particle Size Analyzer
Winner2309C Large-range Modular Wet and Dry Laser Particle Size Analyzer

Winner2309C is intelligent fullly automatic laser particle sizeanalyzer, adopts the most advanced International MIE scatter-ing principle and Fraunhofer diffraction principle, which is integrated model of wet and dry dispersion system. High sensitive and high resolution photoelectric probe system and imported Canon lens optical path ensure the good accuracyand repeatability of particle size distribution. It's widely usedin industrial production quality control departments and research institutions.

Main Specifications

 

General
Optics
Measurement Size
Software Functions
Model Name Winner2309C
Principle Laser light scattering
Analysis Mie and Fraunhofer scattering
Detector Arrangement Log-spaced array, test angle from 0.015 degree to 145 degree
Test Speed Fastest 10 seconds
Refractive Index A wide range of refractive indices are available; any refractive index can be entered.
Sampling Frequency Fastest data acquisition rate of 10kHz
Outer Dimension Main unit: 870mm*340mm*380mm
Wet module: 415mm*280mm*335mm
Dry module: 260mm*245mm*295mm
Net weight Main unit: 32kg
Wet module: 15kg
Dry module: 7kg
Operation Mode SOP Fully automated operation mode
Red Light source Max.4.0MW Fiber, 639nm
Light Source Main laser: High-performance laser λ=639nm, P>2mW
Auxiliary laser: Blue laser λ=405nm, P>2mW
Optical Bench Alignment System Automatic alignment
Optical path Reverse Fourier (Folded optical path)
Laser Safety Class 1
Measurement Range Wet: 0.01-2000μm
Dry: 0.1-2000μm
Sample Injector Wet: Winmodule-201
Dry: Winmodule-301
Number of Channels 106pcs
Accuracy Error Wet: <0.5%; Dry: <1.0% (CRM D50)
Repeatability Error Wet: <0.5%; Dry: <1.0% (CRM D50)
Dispersion Ultrasonic: Frequency: f=40KHz, Power: p=60W (Time adjustable)
Stir: Revolutions speed: 0-3000rpm (Adjustable)
Circulate: Rated flow: 1L-8L/min; Rated power: 120W
Dry Method: Turbulent dispersion, automatic sample introduction, one-click testing
Wet Method:Ultrasonic, mechanical stirring, and built-in circulating dispersion
Sample Tank Volume 600ml
Analysis Pattern Free distribution, R-R distribution, log-normal distribution, and statistical models by category.
Statistical Comparison Statistical comparison of multiple test results. Users can compare and analyze test data from different batches of samples, before and after sample processing, or at different processing times, effectively guiding product quality and cost control.
Data Processing The system performs intelligent statistical analysis and processing of test data, and outputs the most representative test results.
Custom Analysis The system can customize the output of any characteristic particle size between D1 and D100, the cumulative percentage of particles larger or smaller than a certain particle size, and the cumulative percentage of a certain particle size range, so as to meet the different requirements of different industries for particle size testing and characterization methods.
Output Typical particle size values, interval particle size distribution (i.e., differential distribution) data and graphs (histograms or curves), cumulative particle size distribution (i.e., integral distribution) data and curves, etc.
Test Report Test reports can be exported in various formats such as Word, Excel, image (.bmp), text (.txt), and PDF, meeting different requirements for viewing test reports, data reprocessing, and article citation in any situation.
One-click operation Wet method: Activate the automatic operation mode and complete all operations such as water intake, air bubble removal, dispersion, testing, cleaning, and data processing with a single button.
Dry method: Activate the automatic operation mode to complete all operations such as dust collection, air supply, feeding, testing, and data processing with a single click.
Language Chinese and English interface. Other language interfaces can be added according to user requirements.
GMP GMP (Optional)
+ Advantages

(1) Automatic optical path alignment System

It is composed of precise four phase hybrid stepper motor, Itsinching precision is reach to micron level,make optimum opticalpaths to ensure accurate and stable test.

 

(2) Wet and dry, unique separated dispersion module

The instrument adopts a modular design for automatic dry and wetdispersion. Customers can freely assemble it according to the test requirements of sample characteristics. It is simple, convenient and fast.

 

(3) Automatic sample dispersion system

The modular design of dry and wet dispersion shortens the circulation pipeline and prevents the precipitation of large particles. It is not only conducive to the uniform dispersion of samples, but also reduces maintenance costs. And it is conducive to the cleaning and maintenance of equipment.

 

(4) Instrument Software

The unique unconstrained free fitting technology collects scattering dataduring the measurement process and has the ability to automaticallyanalyze multi-modal particle groups. It is not constrained by any function. Particles below 2um are tested in 12 particle size grades with extremelyhigh physical resolution.

 

(5) Optical path design

Adopting the patented inverse Fourier (folded optical path) technology, there ception of scattered light from sample particles is not limited by the focallength of the optical path. The test angle range is 0.015-145 degrees, whicheffectively improves the measurement range and the resolution of theinstrument. The optical path is sealed and has good dustproof performance.

+ Test Principle
Winner2309C Large-range Modular Wet and Dry Laser Particle Size Analyzer 
+ Application
Solid powder, suspension and emulsion. Chemicals, Magnetic Materials, Medicine, Cement, Coatings, Food, Pesticides, Nuclear Industry, Electronics, Battery Materials, Paper, Metallurgy, Ceramics, Building Materials, Cosmetics, Abrasives, Metal and Non-metal Powders, Calcium Carbonate, Talc, Kaolin, Oxidation Particle size testing of powders in their respective industries such as aluminum, rare earth, cemented carbide, catalysts, foaming agents, refractory materials, fillers, graphite, pigments, etc.
Winner2309C Large-range Modular Wet and Dry Laser Particle Size Analyzer
+ Patent Technology

(1). Optical bench design is protected by patent No.- ZL 2014 2 0378380.8.

(2). Three dimensional-optical bench alignment system is protected by patent No.- ZL 2013 2 0835882.4.

(3). MIE scattering principle application patent No.- ZL 2013 2 0812021.4.

(4). Dry particle size analyzer full sealed sample cuvette application is protected by patent No.- ZL.2011 2 0267646.8.

(5). Dual laser beam orthogonal application is protected by patent No.-ZL 2007 2 0025702.0.

(6). Powder dispersion pump design application is protected by patent No.-ZL 2007 2 0018648.7.

(7). Wet circulation installation is protected by patent No.-ZL2010 2 0593526.2.

Contact Us
GET IN TOUCH

Copyright © Jinan Winner Particle Instrument Stock Co., Ltd. All Rights Reserved | sitemap  

ORDER NOW!