Follow Us:
Jinan Winner Particle Instrument Stock Co., Ltd.
Home / Products / Laser Particle Size Analyzer / Micron Particle Size Analyzer
  • Winner-3006 Dry Laser Particle Size Analyzer

  • Winner-3006 Dry Laser Particle Size Analyzer

Winner-3006 Dry Laser Particle Size Analyzer

Winner3006 is a universal dry dispersion laser particle size analyzer, using the scientific structure design and a new generation of dispersion device, the dispersion effect is better than similar instruments. Using MIE scattering theory as the theoretical basis, converging Fourier transform optical path, and with high stability and He-Ne laser high-sensitivity photodetectors ring ensures repeatability and accuracy of test results.

 

This product use air as the dispersing medium, the use of turbulent dispersion principle, with high-precision feeding apparatus and Patent powder injection pumps, No-Oil silent air source, ensure that the sample is thoroughly dispersed. It is applied to any powder material, particularly good for materials occurs chemical reaction in water, or shape change in the liquid. It have same accuracy and repeatability compared with the wet method.



Products Description

Overview:

Winner3006 is a universal dry dispersion laser particle size analyzer, using the scientific structure design and a new generation of dispersion device, the dispersion effect is better than similar instruments. Using MIE scattering theory as the theoretical basis, converging Fourier transform optical path, and with high stability and He-Ne laser high-sensitivity photodetectors ring ensures repeatability and accuracy of test results.

 

This product use air as the dispersing medium, the use of turbulent dispersion principle, with high-precision feeding apparatus and Patent powder injection pumps, No-Oil silent air source, ensure that the sample is thoroughly dispersed. It is applied to any powder material, particularly good for materials occurs chemical reaction in water, or shape change in the liquid. It have same accuracy and repeatability compared with the wet method.


 Main Specifications:

Model Name

Winner3006

Standard

GB/T19077-2016ISO 13320:2009;  Q/0100JWN001-2020

Size Range

0.1-600μm

Channels Number

98

Accuracy error

≤0.5%(Deviation of  D50 on national standard sample)

Repeatability error

≤0.5%(Deviation of  D50 on national standard sample)

Light Source

 High performance laser λ=639nm power p>2mW

Dispersion Method

Dry-turbulence dispersion mode

Operating mode

SOP can be set, one-click automatic test, automatic storage, automatic alignment and other functions

Test Speed

<1min/for each time

Volume

Host:1030*450*325mm

Dispersed modules:260*285*135mm

N.W

33Kg +7Kg


Main Features:

 

1) Unique patent technology of optical path and detection system, greatly improve testing resolution.

Converging Fourier transform optical path patent technology overcome lens aperture restriction on the scattering angle, expand testing range in limited space, and add more secondary integrated photodetectors, which can effectively collect scattered light from all angles in the the corresponding test range, make sure the testing accuracy and reliability within the full range.

 

2)Scientific and automatic dry dispersing system

Turbulence dispersion patented technology and Normal shock shearing effect make particles sufficient dispersion, dispersion core part using wearable ceramics not only improve dispersion system’s working life but ensure more accurate and stable testing result.

 

3) The computer sets the vibration feeding speed to realize one-click control of feeding, which is more convenient and simple.

 

4)Intelligent Operation System realize one key test

Just need put in sample, Dust collection, air supply,feeding and others are all automatic. It only only  reduces workload, but eliminate errors caused by human factors, further improve testing accuracy and authenticity of the testing results.

 

5)Software support

Unique unconstrained free fitting technology make particle analysis not be restricted by any functions, truly reflect particles distribution, ensure accuracy of testing result.

 

6) Data Analysis

① Meet the average, statistics, and comparison of sample test data in different time periods, and obtain the basic parameters of the sample particle size distribution, such as D1-D100, surface area average particle size, volume average particle size, etc.

② Create groups for sample testing to facilitate storage and comparison of sample test data.

 

Application:

Winner3006 Dry laser particle size analyzer used in cement, ceramics, pharmaceuticals, dyes, pigments, fillers, chemical products, catalysts, coal dust, additives, pesticides, explosives, graphite, photographic materials, fuel, metal and non-metal powder, carbonated calcium, kaolin and other powder industry, particularly for materials which occurs chemical reaction, the shape change and the loss in the liquid, such as herbs, magnetic materials and relatively wide distribution and larger particles powders, have more unique applicability and practicality.

 Winner-3006 Dry Laser Particle Size Analyzer

Patents Technology:

 

Optical bench design is protected by patent No.- ZL 2014 2 0378380.8,

Three dimensional-optical bench alignment system is protected by patent No.- ZL 2013 2 0835882.4.

MIE scattering principle application patent No.- ZL 2013 2 0812021.4.

Dry particle size analyzer full sealed sample cuvette application is protected by patent No.- ZL.2011 2 0267646.8.

Powder dispersion pump design application is protected by patent No.-ZL 2007 2 0018648.7


Principle:


Winner-3006 Dry Laser Particle Size Analyzer


CONTACT US
GET IN TOUCH

Copyright © Jinan Winner Particle Instrument Stock Co., Ltd. All Rights Reserved | Sitemap  

ORDER NOW!